Improve battery percentage calculation and reporting
While charging, percentage should only go up, and while discharging, percentage should only go down.
This commit is contained in:
parent
b84a546920
commit
a9f7153fdf
|
@ -69,18 +69,23 @@ void Battery::SaadcEventHandler(nrfx_saadc_evt_t const* p_event) {
|
|||
// p_event->data.done.p_buffer[0] = (adc_voltage / reference_voltage) * 1024
|
||||
voltage = p_event->data.done.p_buffer[0] * (8 * 600) / 1024;
|
||||
|
||||
uint8_t newPercent;
|
||||
if (isFull) {
|
||||
percentRemaining = 100;
|
||||
newPercent = 100;
|
||||
} else if (voltage < battery_min) {
|
||||
percentRemaining = 0;
|
||||
newPercent = 0;
|
||||
} else {
|
||||
percentRemaining = std::min((voltage - battery_min) * 100 / (battery_max - battery_min), isCharging ? 99 : 100);
|
||||
newPercent = std::min((voltage - battery_min) * 100 / (battery_max - battery_min), isCharging ? 99 : 100);
|
||||
}
|
||||
|
||||
if ((isPowerPresent && newPercent > percentRemaining) || (!isPowerPresent && newPercent < percentRemaining) || firstMeasurement) {
|
||||
firstMeasurement = false;
|
||||
percentRemaining = newPercent;
|
||||
systemTask->PushMessage(System::Messages::BatteryPercentageUpdated);
|
||||
}
|
||||
|
||||
nrfx_saadc_uninit();
|
||||
isReading = false;
|
||||
|
||||
systemTask->PushMessage(System::Messages::BatteryMeasurementDone);
|
||||
}
|
||||
}
|
||||
|
||||
|
|
|
@ -42,6 +42,7 @@ namespace Pinetime {
|
|||
bool isFull = false;
|
||||
bool isCharging = false;
|
||||
bool isPowerPresent = false;
|
||||
bool firstMeasurement = true;
|
||||
|
||||
void SaadcInit();
|
||||
|
||||
|
|
|
@ -24,7 +24,7 @@ namespace Pinetime {
|
|||
SetOffAlarm,
|
||||
StopRinging,
|
||||
MeasureBatteryTimerExpired,
|
||||
BatteryMeasurementDone,
|
||||
BatteryPercentageUpdated,
|
||||
};
|
||||
}
|
||||
}
|
||||
|
|
|
@ -349,14 +349,10 @@ void SystemTask::Work() {
|
|||
motorController.RunForDuration(15);
|
||||
break;
|
||||
case Messages::MeasureBatteryTimerExpired:
|
||||
sendBatteryNotification = true;
|
||||
batteryController.Update();
|
||||
break;
|
||||
case Messages::BatteryMeasurementDone:
|
||||
if (sendBatteryNotification) {
|
||||
sendBatteryNotification = false;
|
||||
nimbleController.NotifyBatteryLevel(batteryController.PercentRemaining());
|
||||
}
|
||||
case Messages::BatteryPercentageUpdated:
|
||||
nimbleController.NotifyBatteryLevel(batteryController.PercentRemaining());
|
||||
break;
|
||||
|
||||
default:
|
||||
|
|
|
@ -133,14 +133,12 @@ namespace Pinetime {
|
|||
TimerHandle_t dimTimer;
|
||||
TimerHandle_t idleTimer;
|
||||
TimerHandle_t measureBatteryTimer;
|
||||
bool sendBatteryNotification = false;
|
||||
bool doNotGoToSleep = false;
|
||||
|
||||
void GoToRunning();
|
||||
void UpdateMotion();
|
||||
bool stepCounterMustBeReset = false;
|
||||
static constexpr TickType_t batteryMeasurementPeriod = pdMS_TO_TICKS(10 * 60 * 1000);
|
||||
TickType_t lastBatteryNotificationTime = 0;
|
||||
|
||||
#if configUSE_TRACE_FACILITY == 1
|
||||
SystemMonitor<FreeRtosMonitor> monitor;
|
||||
|
|